The T1R measures three different ways, and each has its own accuracy specification. This article covers what to expect from each mode and the handful of things that affect a reading in practice.
Accuracy by Mode
Digital Tape Measure mode is accurate to ±1/32" across its 16 ft (4.8 m) range. Laser Distance Measure mode is accurate to ±1/16" (1.58 mm) across its 165 ft (50.29 m) range. Digital Level mode reports orientation to within ±0.2°.
These are digital accuracy figures, meaning they describe what the tool reports. How you position the tool against the work matters just as much, which is what the rest of this article covers.
Resolution Is Not the Same as Accuracy
Resolution controls how precisely a measurement is displayed, not how accurately it was taken. You can set fractional increments of 1/2, 1/4, 1/8, 1/16, or 1/32, or decimal precision of .XX, .X, or whole numbers. Setting a coarser resolution does not make the tool less accurate; it rounds what you see. Resolution options are only available when using English units. See [T1R] Measurement Resolution and Tolerances.
Light and Heavy Measurements
On a conventional tape measure, a "light" or "heavy" measurement is one that falls between the marked graduations. There is always a tradeoff between speed and precision here, since 1/16" is far quicker to read than 1/64".
The T1R handles this with an X marker on the display. An X means the measurement lands on a marking. Arrows pointing left or right show which direction you would need to move to hit the nearest mark. This appears only in fractional modes.
Where the Measurement Begins
The single biggest factor in getting the number you expect is knowing which surface the T1R is measuring from. Digital Tape Measure mode references the front of the tool by default, while Laser Distance Measure mode references the back. You can also measure from the back tab or from the projected laser position.
Each reference surface has its own icon on the display, so you can confirm at a glance which one is active before you capture. See [T1R] Where is the T1R Measuring From?
Getting the Best Results
A few practical habits improve consistency. Keep the tool square to the surface you are measuring rather than angled. When using Point to Point over longer distances or to tighter tolerances, a tripod holds the tool steady and produces noticeably better results. And if a reading looks wrong, check the reference surface and modifier icons before assuming the tool is off.
If measurements drift consistently, the blade may need calibrating. See [T1R] Blade Setup (Calibration).