[BOLDR] Capturing Angles

BOLDR records angles as well as lengths. You can type an angle in, or send one from a tool that measures angles: the REEKON T1R, a Bosch GLM in its tilt function, or a Leica DISTO with its tilt display on. Screenshots in this article are from the tablet layout.

Type an angle into a group

  1. Tap the header of the group the angle should go in.

  2. Tap the yellow + button, and under Objects, tap Angle.

  3. The panel shows Unit deg and Add angle:. Type the angle and tap Add. Use ± for a negative angle and the decimal point for part of a degree.

    The Measurements panel for angles with Unit deg, the Add angle display, and a keypad with plus-minus, decimal point, AC, and Del
  4. Add more angles if you like, then tap Save All.

For more on this panel, see Adding a Measurement or Angle Manually.

Angle fields in forms

Forms can have Angle fields. To add one to a form, use Add Form Fields in the form's menu, or tap + > Angle while the form is active and tap Add when BOLDR asks Add Field? The new field is named Angle followed by a number. See Form Field Types Explained.

To fill an Angle field, tap its value to select it, then take the reading, or type the angle as described in Adding a Measurement or Angle Manually.

Which tools send angles

  • REEKON T1R: its level, laser level, and angle finder readings are saved as angles. In the measurement's details they show Level or Laser Level. A target level reading also fills in the description, for example "Target level: 14°". If angle finder readings don't come through, update the T1R's firmware. See Updating Firmware.

  • Bosch GLM: readings from its tilt function are saved as angles.

  • Leica DISTO: turn on the DISTO's tilt display. BOLDR records the tilt only when an Angle field in a form is selected. Anywhere else, the DISTO records the distance.

  • REEKON T1 and T1M: lengths only.

An angle from a T1R or Bosch GLM taken while a group is active lands as an angle tile in that group, like any other reading. See Taking a Measurement with a Connected Tool.

If a reading doesn't match the field

When a form field is selected, BOLDR checks that the reading fits it:

  • Cannot update measurement input: "This reading is an angle — select an angle input". You sent an angle while a length field was selected. Tap an Angle field and measure again.

  • Cannot update angle input: you sent a length while an Angle field was selected. The message tells you what to do for your tool:

    • Bosch: "Switch the GLM to tilt measurement to send an angle"

    • Leica: "Turn on the DISTO's tilt display to send an angle"

    • REEKON tapes: "Use a different tool to measure angles". On a T1R, switch to a level or angle finder reading instead.

Good to know

  • Angles show with a degree sign (°) on tiles and as deg in the details.

  • Angles have no unit choice and no cut options.

  • Angles aren't included in a group's summary or affected by a group formula. See Group Summary and Group Formulas.

  • T1R dual level and post level results are added as construction calculators, not angle tiles. See Using Construction Calculators.